Medidor de pH, CE, TDS y temperatura, rango alto
Medidor de pH, CE, TDS y temperatura, rango alto Medidor de pH, CE, TDS y temperatura, rango alto

PH, EC, TDS and temperature meter, high range

ref: 01ESHI98130 sku: HI98130
  • PH, EC, TDS and temperature meter, high range HANNA mod. HI98130
  • PH range 0-14 EC 0.00-20.00 mS/cm TDS 0.00-10.00 ppt
  • Digital, compact, waterproof and floating
  • Easy replacement of the ph electrode
  • Automatic 1-point or 2-point calibration of ph and 1 EC, TDS
  • Faster, more efficient and accurate solution for all pH/EC/TDS/Temperature controls
€212.75
Free shipping
Free Shipping + info

Technical characteristics

Features of the Combo Waterproof pH/EC/TDS/temperature meter - high range:

The Combo series waterproof pocket instruments, offer high accuracy in pH, EC (conductivity) TDS (dissolved solids in water) and temperature measurements.

It is no longer necessary to use 2 or 3 instruments for these measurements: in fact, these testers display on the tablet the pH or EC/TDS readings automatically compensated in temperature and the temperature value of the sample in degrees Celsius. To obtain more accurate results for each application, the EC/TDS conversion factor can be selected by the user, as well as the temperature compensation coefficient (ß). It is possible to program the ß (Beta) coefficient between 0.0 and 2.4 % per °C, in 0.1 increments.

These meters are waterproof and floatable, and feature a large 2-level display: displays pH/CE/TDS simultaneously. They have automatic shut-off in case of inactivity.

The pH electrode can be easily replaced and has a long life due to the renewable fibre junction. The stainless steel connector of the pH electrode is robust and can be inserted without any difficulty. The pH calibration is automatic with 2 sets of stored buffers: standard 4.01/7.01/10.01 pH or N.I.S.T 4.01/6.86/9.18 pH

(N.I.S.T: National Institute of Standards and Technology)

The graphite EC/TDS probe is not damaged by salts and other aggressive substances and therefore ensures more accurate measurements. For total dissolved solids (TDS) measurements, the conversion factor can be programmed between 0.45 and 1.00 in 0.01 increments.

The fully exposed stainless steel temperature sensor reduces instrument response times; its proximity to the pH/EC/TDS probes increases the accuracy of automatically compensated measurements.

HI98130 HI98130 Meter Specifications Hanna

PH range. 0.00 to 14.00 pH...
EC range. from 0.00 to 20.00 mS/cm.
TDS range. from 0.00 to 10.00 ppt.
Temperature range. 0.0 to 60.0ºC/32.0 to 140.0ºF.
Resolution pH. 0.01 pH.
EC resolution. 0.01 mS/cm.
TDS resolution. 0.01 ppt.
Temperature resolution. 0.1ºC / 0.1 ºF.
Accuracy (at 20ºC) ph. +/- 0.05 pH.
Accuracy (at 20ºC) EC/TDS. +/- 2% R.F.
Accuracy (at 20ºC) temperature. +/- 0.5ºC +/-1ºF.
Temperature compensation. pH: automatic; EC/TDS: automatic with ß adjustable from 0.0 to 2.4 % /ºC.
PH calibration. automatic in 1 or 2 points with 2 sets of memorised buffers (pH 4.01/7.01/10.01 or 4.01/6.86/9.18).
Automatic 1-point EC/TDS. automatic in 1 point.
EC/TDS. selectable from 0.45 to 1.00.
PH electrode. HI 73127 (replaceable; included).
Working conditions. 0 to 50ºC; R.H. max. 100 %.
Battery type / life. 4 x 1.5 V / approx. 100 hours continuous use; auto-off after 8 minutes of inactivity.
Dimensions 163 x 40 x 26 mm.
Weight. 100 g.

Supplied complete with protective cap, electrode replacement key, batteries and instructions.

Data Sheet

Parameters
3 parameters
Type of case
Digital

Expert Review