Spare parts CTX e-Series pH
- Seko roller holder RIC0151035
- Seko Santoprene peristaltic tube 9900090057 (6x10 mm, 4x6 connection)
- Hanna HI2114P pH electrode, 2 m
- PH electrode kit Astralpool
- Seko pH electrode, 1.5 m 9900105001
- Seko pH 7 buffer solution (50 ml) 9900102002
- Seko PSS3 long probe holder 9900106670
- Collar for PVC pipe 50-1/2"
| Position | Product | Quantity | Unit price |
|---|---|---|---|
| 1 |
Seko roller holder RIC0151035 |
Regular price
15,95 €
Sale price
Regular price
|
|
| 2 |
Seko Santoprene peristaltic tube 9900090057 (6x10 mm, 4x6 connection) |
Regular price
18,90 €
Sale price
Regular price
|
|
| 3 |
Hanna HI2114P pH electrode, 2 m |
Regular price
76,90 €
Sale price
Regular price
|
|
| 4 |
PH electrode kit Astralpool |
Regular price
79,90 €
Sale price
Regular price
|
|
| 5 |
Seko pH electrode, 1.5 m 9900105001 |
Regular price
74,90 €
Sale price
Regular price
|
|
| 6 |
Seko pH 7 buffer solution (50 ml) 9900102002 |
Regular price
5,99 €
Sale price
Regular price
|
|
| 7 |
Seko PSS3 long probe holder 9900106670 |
Regular price
23,95 €
Sale price
Regular price
|
|
| 8 |
Collar for PVC pipe 50-1/2" |
Regular price
2,59 €
Sale price
Regular price
|
Replacement Parts for the CTX, and e-Series pH Pumps: Probe, Peristaltic Tube, and Calibration
The e-Series pH from CTX is one of the most widely installed pH control pumps in residential pools: peristaltic, compact, and featuring a pH probe integrated into the circuit. Maintenance is limited to two consumables and a routine procedure: the peristaltic tube, the pH probe, and periodic calibration to ensure the equipment operates reliably.
On this page, you’ll find replacement parts with prices — probes, Santoprene tubing, roller holders, probe holders, collars, and calibration solution — as well as a setup guide that answers the most common questions about use: how to calibrate, how often, and what to do when the pH reading on the display doesn’t match that of the analyzer.
A useful technical note: the e-Series is built on the Seko, so its head replacement parts (tube and roller holders) are the same as those for that series.
Related categories: Dosage pump replacement parts · Automatic pH control · Dosage pumps · Dosage accessories · Water analysis · Technical service
The pH probe: the most sought-after replacement part
The probe (or electrode) is the component that determines whether your pool is properly treated. When it wears out, the system continues to operate but provides inaccurate readings—and doses acid based on incorrect data. Typical service life: 2–3 seasons.
| Probe | Approximate price | Notes |
|---|---|---|
| Seko pH Electrode, 1.5 m | €74.90 | Seko platform electrode with a 1.5-meter cable. |
| Hanna HI2114P pH Electrode (2 m) | €76.90 | Version with a 2-meter cable, useful when the distance between the probe holder and the instrument is greater. |
| pH Electrode Kit Astralpool | €79.90 | Complete electrode kit. |
Before ordering, measure the distance between the probe installation point and the equipment: this will determine whether the 1.5-meter cable is long enough or if you need the 2-meter one. Also, check the connector type on your current probe.
Head, probe holder, and installation
| Replacement | Estimated price | What it’s used for |
|---|---|---|
| Santoprene peristaltic tube (6x10 mm, 4x6 connection) | €18.90 | The No. 1 consumable. This is the tube that the rollers squeeze to pump fluid. It hardens when exposed to acid and loses flow capacity. Replace every 1–2 seasons. |
| Roller holder | €15.95 | The rotor assembly with the rollers that compress the tube. Replace if the rollers turn with difficulty or show signs of wear. |
| Long PSS3 Probe Holder | €23.95 | The housing where the probe is installed in the pipe. Replace if it is cracked or no longer seals properly. |
| Collar for 50-1/2” PVC pipe | €2.59 | The connection collar for 50 mm pipe with a 1/2” outlet. |
| pH 7 buffer solution (50 ml) | €5.99 | The calibration standard. Replace it every season: an old solution calibrates poorly. |
Calibrating the e-Series pH: the ritual that keeps everything accurate
This is the most common question about this device, so let’s get right to the point. Calibration is about teaching the pump what a known pH value is so it can accurately interpret its measurements.
When to do it:
- At the start of each season, always
- Every 2–3 months during the season
- Whenever you replace the probe
- When the pH reading on the display does not match that of your reference analyzer
Basically:
- Stop the dosing and remove the probe from its probe holder
- Rinse the tip with clean water and gently dry it, without rubbing the bulb
- Immerse it in the standard solution (pH 7) and wait for the reading to stabilize
- Confirm the calibration on the device by following the menu sequence
- Rinse, reattach the probe to the probe holder, and resume dosing
Two tips to avoid disappointment:
- The calibration solution has expired. This is the number one cause of failed calibrations: if the equipment cannot calibrate, try using fresh solution before suspecting the probe
- Don’t let the probe dry out. An electrode that spends hours exposed to the air with a dry bulb rarely recovers. If you remove it, store it with its cap and storage solution
For the exact menu sequence for your specific model, consult the manufacturer’s manual or contact us: the steps vary slightly between models in the series.
Quick Diagnosis: From Symptom to Part
| Symptom | Most Likely Cause | What to Check |
|---|---|---|
| The pH reading on the display does not match the analyzer | Probe is out of calibration or worn out | Calibrate with a new solution; if it drifts over time, replace the probe |
| I can’t calibrate the equipment | Solution has expired or the probe is worn out | Use a new solution first; then check the probe |
| The reading takes a long time to stabilize | Sensor at the end of its service life | Sensor |
| Dosing less than programmed | Hardened peristaltic tube | Santoprene tube |
| Pumps but does not draw in product | Expired tubing, clogged foot filter, or air | Tube, foot filter, suction connections |
| Product leaking from the head | Punctured hose | Hose; check inside the head |
| The rollers turn with difficulty or make noise | Worn roller holder | Roller holder |
| Leak at the probe connection point | Probe holder or its seal | Probe holder |
| Level error when the tank is full | Level probe or suction tube | Suction circuit |
Maintenance of the e-Series pH
- Flush the circuit with clean water at the end of the season. Leaving acid to sit for six months causes the tubing to harden and the injection point to crystallize. This is the most effective way to prevent breakdowns
- Check the foot filter every time you change the bottle
- Keep the probe moist if you disassemble the unit: use the cap and preservative solution
- Replace the calibration solution every season, even if there is liquid left in the bottle
- Monitor the injection point: limescale buildup occurs gradually
- Always weargloves and goggles when opening the head: there are traces of concentrated product inside
Can’t find a replacement part for your e-Series pH CTX, or do you need help with calibration? Call us at 91 128 55 90 or contact us via the contact form, specifying the exact model of your equipment and, if it’s a reading issue, what the display shows on your analyzer. And keep these two rules in mind to ensure this pump works properly: calibrate it at least at the start of the season and replace the standard solution every year. See also replacement parts for dosing pumps, automatic pH control, water analysis, and technical service.