A hardened or deformed O-ring no longer seals: the pump drips or draws in air and loses flow. This is the 118 x 4 mm O-ring the manufacturer uses on several AstralPool pumps.
Spare part details
- Manufacturer's description: JUNTA TORICA D. 118X4
- Manufacturer code: 4405010437
- EAN: 8420382119664
- Manufacturer: AstralPool (Fluidra)
This code is the seal only.
Compatible equipment
The manufacturer lists this part in the official exploded views of these pumps and units:
- Astral Alaska: 41607, 41608, 41609, 41610, 41611
- Sena SS: 25461, 25461-0810, 25462, 25462-0810, 25463, 25463-0810, 25464, 25464-0810, 25465, 25465-0810, 25466, 25466-0810, 25467, 25467-0810, 25468, 25468-0810
- Astral Compact SS: 25470, 25471, 35612
- Asiatic Min: 04010201, 04010202, 04010203, 04010204, 04010205
- B.M.I SS: 30891, 30892, 30893, 30894, 30895, 30896, 30897, 30898
- B.MN.G.: 74471R1194, 74473R1194, 74474R1194, 74476R1194
- America: SA033M, SA033M-IF, SA050M, SA050M-IF, SA050T, SA050T-IF, SA075M, SA075M-IF, SA075T, SA075T-IF, SA100M, SA100M-IF, SA100T, SA100T-IF, SA125M, SA125M-IF, SA125T, SA125T-IF
- New Mini Pump: NEWMP025M, NEWMP025M-IF, NEWMP033M, NEWMP033M-IF, NEWMP050M, NEWMP050M-IF, NEWMP075M, NEWMP075M-IF
- Monobloc Millennium Top: 23342, 23343, 23344, 27805, 28299
How to identify your model
Your pump code is shown on the rating plate and in your purchase documents. The five exploded views of the Astral Alaska (41607 to 41611) share this part; they differ in motor parts, such as the impeller and the capacitor, depending on the power. If you cannot find the code, send us a photo of the rating plate before ordering and we will confirm it.
Replacement
Fluidra does not publish a replacement procedure for this part; the steps below are the usual ones. If in doubt, ask us before you start.
- Stop the pump and disconnect it from the mains at the electrical panel.
- If the pump is below water level, close the suction and discharge valves.
- Remove the damaged part.
- Fit the new part in the same position.
- Open the valves, switch the pump on and check that it primes and does not leak.