The pump body is the housing through which the water flows inside the pump. If it is cracked or leaks, it must be replaced.
Spare part details
- Manufacturer's description: CUERPO BOMBA
- Manufacturer code: 4405010405
- EAN: 8420382112634
- Manufacturer: AstralPool (Fluidra)
According to the exploded view, on pumps made before 05/2024 the pump body screw set (4405011440) must also be replaced.
Compatible equipment
The manufacturer lists this part in the official exploded views of these pumps and units:
- Sena SS: 25461, 25461-0810, 25462, 25462-0810, 25463, 25463-0810, 25464, 25464-0810, 25465, 25465-0810, 25466, 25466-0810, 25467, 25467-0810, 25468, 25468-0810
How to identify your model
Your pump or unit code is shown on its rating plate and in your purchase documents. Check that it appears in the list above. On the Sena SS, codes ending in -0810 are the 60 Hz versions. If you cannot find the code, send us a photo of the rating plate before ordering and we will confirm it.
Replacement
Fluidra does not publish a replacement procedure for this part; the steps below are the usual ones. If in doubt, ask us before you start. If you have no experience with electric motors, we recommend having a professional do it.
- Stop the pump and disconnect it from the mains at the electrical panel.
- If the pump is below water level, close the suction and discharge valves.
- Remove the damaged part.
- Fit the new part in the same position.
- Open the valves, switch the pump on and check that it primes and does not leak.