The motor fan and its cover move air to cool the motor. If the fan is broken or the cover damaged, the motor is cooled less effectively, can run hotter than normal and make rubbing noises. In the Tifon 1 and Silen 2 exploded views, the 300 M version uses a different fan (0000010367).
Spare part details
- Manufacturer description: VENTILADOR
- ESPA code: 1041 (ref. 0000001041)
- Manufacturer: ESPA
Compatible pumps
According to ESPA's official exploded views, this spare part appears in the following pumps (exploded-view code in brackets):
- 15244 BM80 461/ESP (B84)
- 15245 BM80 462/ESP (B85)
- 15246 BM80 461/ESP (B86)
- 15247 BM80 462/ESP (B87)
- 15248 BM80 462/ESP (B08)
- 16093 BM80 461/ESP (A93)
- 16094 459/ESP (A94)
- 16095 458/ESP (A95)
- 16096 459/ESP (A96)
- 16097 459/ESP (A97)
- AQUAX 200 VV (AQUAX200VV)
- AQUAX 200-300 (AQUAX23)
- ASPIRA 30 (AS3)
- ASPIRA 30 3/STD 343/COM (AS31)
- ASPRI 25 - 25 B 50/60Hz (S25)
- ASPRI 35 (A35)
- ASPRI 35 B (A35B)
- ASPRI 35 N (A35N)
- ASPRI 45 N (A45N)
- ASTRAL GLASS-PLUS (AG)
- BARI 10 (ACTUAL) (BAR11)
- BARI 10 2442-2443-2444-2445/ESP (BAR10)
- BARI 20 (ACTUAL) (BAR21)
- BARI 20 2444-2445/ESP (BAR20)
- BLAUMAR S2 (BLAS2)
- CPP 25 1551/ESP (R251)
- CPP 30 1552/ESP (P32)
- CPS 30 1554/ESP (M33)
- ECPD MERCADONA (ECPDMER)
- ESCATOP/ESCAWAT (ESCA)
- FIN SP1 1250/ESP (FIN1)
- FLIPPER 1 220 60 66/STD (F10S)
- FLIPPER 1S (F1)
- FLIPPER 2NS (FA2)
- FLIPPER 2NS 61/STD 652/COM (FA20)
- FLIPPER 2NS 70/STD 542/COM (FA21)
- FLIPPER NS (FA)
- GEMA 2503-2504/ESP (GEM)
- IPE2 2424-2425/ESP (IP2)
- M30 (2630/ESP) (M32)
- M40 (2630/ESP) (M41)
- MISTRAL 33 5M // 90 4M // 150 4M (A0129)
- MULTI 30 (M30)
- MULTI 35 N 50/60Hz (MN35)
- MULTI 40 (M40)
- MULTI 45 N (MN45)
- MULTI 55 N 50Hz (MN55)
- MV10 2470/ESP 2471/ESP (MV10)
- MV15 (A0003)
- MV20 2471/ESP (MV20)
- MV25 (A0004)
- NOXPLUS 2 (NOXPLUS2)
- PISCIS 4 50Hz (PI4)
- POSEIDON 50Hz (POS)
- PRISMA 25 50/60Hz (R25)
- PRISMA 30 (P30)
- PRISMA 35 (P35)
- PRISMA 35 N 50/60Hz (P35N)
- PRISMA 40 (P40)
- PRISMA 45 N 50/60Hz (RN45)
- ROMA 10 (ACTUAL) (ROM11)
- ROMA 10 2446-2447/ESP (ROM)
- ROMA 20 (ACTUAL) (RO1)
- ROMA 20 2447/ESP (RO2)
- SILEN 2 50/60Hz (SL2)
- SILEN S2 (SILEN S2)
- SILENPLUS 2 M 50/60Hz (A0102)
- SILENPLUS 3 M 50/60Hz (A0103)
- STARPUMP PRO 014976/ESP (STARPUMP)
- STORM (STRM)
- T2 (T2)
- TEMA SM (TEP)
- TIFON 1 1014/ESP 1015/ESP (TI6)
- TIFON 1 165/STD 1201/COM (TI4)
- TIFON 1 248/ESP 249/ESP 852/ESP (TI1-)
- TIFON 1 248/ESP 249/ESP 852/ESP (TI3)
- TIFON 1 50/60Hz (TI1)
- TIFON 1 961/ESP (TIE)
- TIFON 1 972/973/978/ESP (TI7)
- TIFON 1 975/ESP (TI8)
- TIFON 1014/ESP (TI5)
- TIFON 426/ESP 427/ESP (TI2)
- TIGER 100/150/200/300 (TGR)
- TV2 (TV2)
- TYPHOON 972-973-975/ESP (TYP)
- TYPHOON T 50Hz 010934/ESP (A0095)
- VEGANOX 65 (VGN)
- VL10 2740/ESP (VL10)
- VM 6 2505/ESP (VM6)
- WIPER 3 (W3)
How to identify your pump model
- Find the rating plate, a label attached to the motor body.
- Note the model shown on it and compare it with the list above.
- If the plate is illegible or you cannot find your model, send us a photo of the plate and the pump and we will confirm it before you order.
How to replace it
- Stop the pump and disconnect it from the power supply.
- Remove the fan cover screws and take the cover off.
- If you are replacing the fan, pull it off the motor shaft, taking care not to damage the shaft.
- Fit the new part in the same position.
- Turn the shaft by hand and check that the fan turns freely without rubbing against the cover.
- Refit the cover, reconnect the pump and check that it runs without unusual noises.