The terminal box houses the motor's electrical connections and protects them from water and dust. If the box or its cover is broken, the connections are exposed to moisture.
Spare part details
- Manufacturer's description: CJTO. CAJA BORNES II
- Manufacturer code: 4405011213
- EAN: 8435283917783
- Manufacturer: AstralPool (Fluidra)
Not every exploded view uses this terminal box: exploded view 51865, for example, lists a different part, 4405011122 (CJTO. CAJA BORNES III). Check that your pump code appears in the list below.
Compatible equipment
The manufacturer lists this part in the official exploded views of these pumps and units:
- Astral Alaska: 41607, 41608, 41609, 41610, 41611
- Astral Alaska Max: 41597, 41598, 41599, 41601, 41603, 41605
- Astral Alaska Plus: 51858, 51860, 51862, 51864, 51866, 51868
- Asiatic Min: 04010201, 04010202, 04010203, 04010204, 04010205
- Colusa: 70574, 70575, 70576, 70578, 70580, 70582
- MRT: 04010M01, 04010M02, 04010M03, 04010M04, 04010M05, 04010M06
- Marathon: 70716, 70717, 70718
How to identify your model
Your pump code is shown on the rating plate and in your purchase documents. Check that it appears in the list above. On the portal, Alaska Max exploded view 41605 refers to Alaska Plus code 51868. If you cannot find the code, send us a photo of the rating plate before ordering and we will confirm it.
Replacement
Fluidra does not publish a replacement procedure for this part; the steps below are the usual ones. If in doubt, ask us before you start. If you have no experience with electric motors, we recommend having a professional do it.
- Stop the pump and disconnect it from the mains at the electrical panel.
- Open the terminal box and take a photo of the connections before removing any wire.
- Remove the damaged set.
- Fit the new set in the same position and connect the wires as they were.
- Close the terminal box, switch the pump on and check that it starts normally.